TITLE 40 - PROTECTION OF ENVIRONMENT
CHAPTER I - ENVIRONMENTAL PROTECTION AGENCY
SUBCHAPTER C - AIR PROGRAMS
PART 60 - STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES
subpart bbbb - EMISSION GUIDELINES AND COMPLIANCE TIMES FOR SMALL MUNICIPAL WASTE COMBUSTION UNITS CONSTRUCTED ON OR BEFORE AUGUST 30, 1999
Table 8 to Subpart BBBB of Part 60 - Model Rule - Requirements for Stack Tests
---------------------------------------------------------------------------------------------------------------- Use the following Use the following methods in appendix A methods in appendix A To measure the following pollutants of this part to of this part to Also note the following determine the sampling measure pollutant additional information location concentration ---------------------------------------------------------------------------------------------------------------- 1. Organics Dioxins/Furans................. Method 1.............. Method 23 a........... The minimum sampling time must be 4 hours per test run while the municipal waste combustion unit is operating at full load.
2. Metals Cadmium........................ Method 1.............. Method 29 a........... Compliance testing must be performed while the municipal waste combustion unit is operating at full load.
Lead........................... Method 1.............. Method 29 a........... Compliance testing must be performed while the municipal waste combustion unit is operating at full load.
Mercury........................ Method 1.............. Method 29 a........... Compliance testing must be performed while the municipal waste combustion unit is operating at full load.
Opacity........................ Method 9.............. Method 9.............. Use Method 9 to determine compliance with opacity limits. 3-hour observation period (thirty 6-minute averages).
Particulate Matter............. Method 1.............. Method 5 or 29........ The minimum sample volume must be 1.0 cubic meters.
The probe and filter holder heating systems in the sample train must be set to provide a gas temperature no greater than 160 14 C. The minimum sampling time is 1 hour.
3. Acid Gases b Hydrogen Chloride.............. Method 1.............. Method 26 or 26A a.... Test runs must be at least 1 hour long while the municipal waste combustion unit is operating at full load.
4. Other b Fugitive Ash................... Not applicable........ Method 22 (visible The three 1-hour emissions). observation period must include periods when the facility transfers fugitive ash from the municipal waste combustion unit to the area where the fugitive ash is stored or loaded into containers or trucks.
---------------------------------------------------------------------------------------------------------------- a Must simultaneously measure oxygen (or carbon dioxide) using Method 3A or 3B in appendix A of this part.
b Use CEMS to test sulfur dioxide, nitrogen oxide, and carbon monoxide. Stack tests are not required except for quality assurance requirements in Appendix F of this part.