40 CFR Table 3 to Subpart JJJJJ of Part 63 - Requirements for Performance Tests

Text


TITLE 40 - PROTECTION OF ENVIRONMENT

CHAPTER I - ENVIRONMENTAL PROTECTION AGENCY

PART 63 - NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES

subpart jjjjj - NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR BRICK AND STRUCTURAL CLAY PRODUCTS MANUFACTURING

Table 3 to Subpart JJJJJ of Part 63 - Requirements for Performance Tests

As stated in 63.8445, you must conduct each performance test in the following table that applies to you.

------------------------------------------------------------------------ According to the For each . . . You must . . . Using . . . following requirements . . .

------------------------------------------------------------------------ 1. Kiln........... a. Select Method 1 or 1A of Sampling locations of 40 CFR part 60, sites must sampling ports appendix A. be located and the number of at the traverse points. outlet of the APCD and prior to any releases to the atmosphere for all affected sources. If you choose to meet the percent emission reduction requirements for HF or HCl, a sampling site must also be located at the APCD inlet.

b. Determine Method 2 of 40 CFR You may use velocities and part 60, appendix Method 2A, volumetric flow A. 2C, 2D, 2F, rate. or 2G of 40 CFR part 60, appendix A, as appropriate, as an alternative to using Method 2 of 40 CFR part 60, appendix A.

c. Conduct gas Method 3 of 40 CFR You may use molecular weight part 60, appendix Method 3A or analysis. A. 3B of 40 CFR part 60, appendix A, as appropriate, as an alternative to using Method 3 of 40 CFR part 60, appendix A.

d. Measure Method 4 of 40 CFR ............

moisture content part 60, appendix of the stack gas. A.

e. Measure HF and Method 26A of 40 Conduct the HCl emissions. CFR part 60, test while appendix A; or operating at the maximum production level. You may use Method 26 of 40 CFR part 60, appendix A, as an alternative to using Method 26A of 40 CFR part 60, appendix A, when no acid PM (e.g., HF or HCl dissolved in water droplets emitted by sources controlled by a WS) is present.

Method 320 of 40 Conduct the CFR part 63, test while appendix A. operating at the maximum production level. When using Method 320 of 40 CFR part 63, appendix A, you must follow the analyte spiking procedures of section 13 of Method 320 of 40 CFR part 63, appendix A, unless you can demonstrate that the complete spiking procedure has been conducted at a similar source.

f. Measure PM Method 5 of 40 CFR Conduct the emissions. part 60, appendix test while A. operating at the maximum production level.

2. Kiln that is Determine the Production data You must complying with production rate collected during measure and production-based during each test the performance record the emission limits. run in order to tests (e.g., no. production determine of pushes per rate, on a compliance with hour, no. of fired- production-based bricks per kiln product emission limits. car, weight of a basis, of typical fired the affected brick). source for each of the three test runs.

3. Kiln equipped a. Establish the Data from the You must with a DLA. operating limit pressure drop continuously for the average measurement measure the pressure drop device during the pressure across the DLA. performance test. drop across the DLA, determine and record the block average pressure drop values for the three test runs, and determine and record the 3-hour block average of the recorded pressure drop measurements for the three test runs.

b. Establish the Data from the You must operating limit limestone feeder ensure that for the limestone during the you maintain feeder setting. performance test. an adequate amount of limestone in the limestone hopper, storage bin (located at the top of the DLA), and DLA at all times during the performance test. You must establish your limestone feeder setting one week prior to the performance test and maintain the feeder setting for the one-week period that precedes the performance test and during the performance test.

c. Document the Records of source and grade limestone of limestone used. purchase.

4. Kiln equipped Establish the Data from the lime For with a DIFF or operating limit feeder during the continuous DLS/FF. for the lime performance test. lime feeder setting. injection systems, you must ensure that lime in the feed hopper or silo and to the APCD is free-flowing at all times during the performance test and record the feeder setting for the three test runs.

If the feed rate setting varies during the three test runs, determine and record the average feed rate from the three test runs.

5. Kiln equipped a. Establish the Data from the You must with a WS. operating limit pressure drop continuously for the average measurement measure the scrubber pressure device during the scrubber drop. performance test. pressure drop, determine and record the block average pressure drop values for the three test runs, and determine and record the 3-hour block average of the recorded pressure drop measurements for the three test runs.

b. Establish the Data from the pH You must operating limit measurement continuously for the average device during the measure the scrubber liquid performace test. scrubber pH. liquid pH, determine and record the block average pH values for the three test runs, and determine and record the 3-hour block average of the recorded pH measurements for the three test runs.

c. Establish the Data from the flow You must operating limit rate measurement continuously for the average device during the measure the scrubber liquid performance test. scrubber flow rate. liquid flow rate, determine and record the block average flow rate values for the three test runs, and determine and record the 3-hour block average of the recorded flow rate measurements for the three test runs.

6. Kiln equipped Establish the Data from the You must with a WS that operating limit chemical feed continuously includes chemical for the average rate measurement measure the addition to the scrubber chemical device during the scrubber water. feed rate. performance test. chemical feed rate, determine and record the block average chemical feed rate values for the three test runs, and determine and record the 3-hour block average of the recorded chemical feed rate measurements for the three test runs.

------------------------------------------------------------------------