Table 7 to Subpart JJJ of Part 63 - Group 1 Batch Process Vents and Aggregate Batch Vent Streams - Monitoring, Recordkeeping, and Reporting Requirements
---------------------------------------------------------------------------------------------------------------- Recordkeeping and reporting requirements Control device Parameters to be monitored for monitored parameters ---------------------------------------------------------------------------------------------------------------- Thermal incinerator................... Firebox temperature a......... 1. Continuous records as specified in 63.1326(e)(1).b 2. Record and report the average firebox temperature measured during the performance test_NCS.c 3. Record the batch cycle daily average firebox temperature as specified in 63.1326(e)(2).
4. Report all batch cycle daily average temperatures that are below the minimum operating value established in the NCS or operating permit and all instances when monitoring data are not collected_PR.d e Catalytic incinerator................. Temperature upstream and 1. Continuous records as specified in downstream of the catalyst 63.1326(e)(1).b bed. 2. Record and report the average upstream and bed downstream temperatures and the average temperature difference across the catalyst bed measured during the performance test_NCS.c 3. Record the batch cycle daily average upstream temperature and temperature difference across catalyst bed as specified in 63.1326(e)(2).
4. Report all batch cycle daily average upstream temperatures that are below the minimum upstream value established in the NCS or operating permit_PR.d e 5. Report all batch cycle daily average temperature differences across the catalyst bed that are below the minimum difference established in the NCS or operating permit_PR.d, e 6. Report all instances when monitoring data are not collected.e Boiler or Process Heater with a design Firebox temperature a......... 1. Continuous records as specified in heat input capacity less than 44 63.1326(e)(1).b megawatts and where the batch process 2. Record and report the average firebox vents or aggregate batch vent streams temperature measured during the are not introduced with or used as performance test_NCS.c the primary fuel. 3. Record the batch cycle daily average firebox temperature as specified in 63.1326(e)(2).d 4. Report all batch cycle daily average temperatures that are below the minimum operating value established in the NCS or operating permit and all instances when monitoring data are not collected_PR.d e Flare................................. Presence of a flame at the 1. Hourly records of whether the monitor pilot light. was continuously operating during batch emission episodes, or portions thereof, selected for control and whether a flame was continuously present at the pilot light during said periods.
2. Record and report the presence of a flame at the pilot light over the full period of the compliance determination_NCS.c 3. Record the times and durations of all periods during batch emission episodes, or portions thereof, selected for control when all flames at the pilot light of a flare are absent or the monitor is not operating.
4. Report the times and durations of all periods during batch emission episodes, or portions thereof, selected for control when all flames at the pilot light of a flare are absent_PR.d Scrubber for halogenated batch process a. pH of scrubber effluent, 1. Continuous records as specified in vents or aggregate batch vent and. 63.1326(e)(1).b strreams (Note: Controlled by a 2. Record and report the average pH of combustion device other than a flare). the scrubber effluent measured during the performance test_NCS.c 3. Record the batch cycle daily average pH of the scrubber effluent as specified in 63.1326(e)(2).
4. Report all batch cycle daily average pH values of the scrubber effluent that are below the minimum operating value established in the NCS or operating permit and all instances when monitoring data are not collected_PR.d e b. Scrubber liquid and gas 1. Records as specified in flow rates. 63.1326(e)(1).b 2. Record and report the scrubber liquid/ gas ratio averaged over the full period of the performance test_NCS.c 3. Record the batch cycle daily average scrubber liquid/gas ratio as specified in 63.1326(e)(2).
4. Report all batch cycle daily average scrubber liquid/gas ratios that are below the minimum value established in the NCS or operating permit and all instances when monitoring data are not collected_PR.d e Absorber f............................ a. Exit temperature of the 1. Continuous records as specified in absorbing liquid, and. 63.1326(e)(1).b 2. Record and report the average exit temperature of the absorbing liquid measured during the performance test_NCS.c 3. Record the batch cycle daily average exit temperature of the absorbing liquid as specified in 63.1326(e)(2) for each batch cycle.
4. Report all the batch cycle daily average exit temperatures of the absorbing liquid that are above the maximum operating value established in the NCS or operating permit and all instances when monitoring data are not collected_PR.d e b. Exit specific gravity for 1. Continuous records as specified in the absorbing liquid. 63.1326(e)(1).b 2. Record and report the average exit specific gravity measured during the performance test_NCS.c 3. Record the batch cycle daily average exit specific gravity as specified in 63.1326(e)(2).
4. Report all batch cycle daily average exit specific gravity values that are above the maximum operating value established in the NCS or operating permit and all instances when monitoring data are not collected_PR.d e Condenser f........................... Exit (product side) 1. Continuous records as specified in temperature. 63.1326(e)(1).b 2. Record and report the average exit temperature measured during the performance test_NCS.c 3. Record the batch cycle daily average exit temperature as specified in 63.1326(e)(2).
4. Report all batch cycle daily average exit temperatures that are above the maximum operating value established in the NCS or operating permit and all instances when monitoring data are not collected_PR.d e Carbon Adsorber f..................... a. Total regeneration steam 1. Record the total regeneration steam flow or nitrogen flow, or flow or nitrogen flow, or pressure for pressure (gauge or absolute) each carbon bed regeneration cycle.
during carbon bed 2. Record and report the total regeneration cycle(s), and. regeneration steam flow or nitrogen flow, or pressure during carbon bed regeneration cycle measured during the performance test_NCS.c 3. Report all carbon bed regeneration cycles when the total regeneration steam flow or nitrogen flow, or pressure is above the maximum value established in the NCS or operating permit_PR.d e b. Temperature of the carbon 1. Record the temperature of the carbon bed after regeneration and bed after each regeneration and within within 15 minutes of 15 minutes of completing any cooling completing any cooling cycle(s).
cycle(s).
2. Record and report the temperature of the carbon bed after each regeneration and within 15 minutes of completing any cooling cycle(s) measured during the performance test_NCS.c 3. Report all carbon bed regeneration cycles when the temperature of the carbon bed after regeneration, or within 15 minutes of completing any cooling cycle(s), is above the maximum value established in the NCS or operating permit_PR.d e All control devices................... a. Diversion to the atmosphere 1. Hourly records of whether the flow from the control device or. indicator was operating during batch emission episodes, or portions thereof, selected for control and whether a diversion was detected at any time during said periods as specified in 63.1326(e)(3).
2. Record and report the times of all periods during batch emission episodes, or portions thereof, selected for control when emissions are diverted through a bypass line or the flow indicator is not operating_PR.d b. Monthly inspection of 1. Records that monthly inspections were sealed valves.. performed as specified in 63.1326(e)(4)(i).
2. Record and report all monthly inspections that show the valves are in the diverting position or that a seal has been broken_PR.d Absorber, condenser, and carbon Concentration level or reading 1. Continuous records as specified in Adsorber (as an alternative to the indicated by an organic 63.1326(e)(1).b requirements previously presented in monitoring device at the 2. Record and report the average batch this table). outlet of the control device. vent concentration level or reading measured during the performance test_NCS.c 3. Record the batch cycle daily average concentration level or reading as specified 63.1326(e)(2).
4. Report all batch cycle daily average concentration levels or readings that are above the maximum value established in the NCS or operating permit and all instances when monitoring data are not collected_PR.d e ---------------------------------------------------------------------------------------------------------------- a Monitor may be installed in the firebox or in the ductwork immediately downstream of the firebox before any substantial heat exchange is encountered.
b ``Continuous records'' is defined in 63.111.
c NCS = Notification of Compliance Status described in 63.1335(e)(5).
d PR = Periodic Reports described in 63.1335(e)(6).
e The periodic reports shall include the duration of periods when monitoring data are not collected as specified in 63.1335(e)(6)(iii)(C).
f Alternatively, these devices may comply with the organic monitoring device provisions listed at the end of this table.