40 CFR 761.243 - Standard wipe sample method and size. - Regulations - VLEX 19832936

40 CFR 761.243 - Standard wipe sample method and size.

Actualizado a:July 2013
CONTENT

Title 40: Protection of Environment

CHAPTER I: ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)

SUBCHAPTER R: TOXIC SUBSTANCES CONTROL ACT

PART 761: POLYCHLORINATED BIPHENYLS (PCBs) MANUFACTURING, PROCESSING, DISTRIBUTION IN COMMERCE, AND USE PROHIBITIONS

Subpart M: Determining a PCB Concentration for Purposes of Abandonment or Disposal of Natural Gas Pipeline: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples

761.243 - Standard wipe sample method and size.(a) Collect a surface sample from a natural gas pipe segment or pipeline section using a standard wipe test as defined in ? 761.123. Detailed guidance for the entire wipe sampling process appears in the document entitled, ?Wipe Sampling and Double Wash/Rinse Cleanup as Recommended by the Environmental Protection Agency PCB Spill Cleanup Policy,? dated June 23, 1987 and revised on April 18, 1991. This document is available on EPA's Web site at http://www.epa.gov/pcb, or from the Program Management, Communications, and Analysis Office, Office of Resource Conservation and Recovery (5305P), Environmental Protection Agency, 1200 Pennsylvania Ave., NW., Washington, DC 20460-0001.

(b) Collect a surface sample from a minimum surface area of 100 cm2 at each sampling site selected. The EPA Regional Administrator may approve, in writing, requests to collect a sample from smaller surface areas, when <100 cm2 of surface eligible for sampling is present; e.g., when sampling a small diameter pipe, a small valve, or a small regulator. When smaller surfaces are sampled, convert the measurement to the equivalent measurement for 100 cm2 for purposes of comparison to standards based on 100 cm2.

[63 FR 35462, June 29, 1998, as amended at 72 FR 57241, Oct. 9, 2007; 74 FR 30235, June 25, 2009]