Table 4 to Subpart DD of Part 63 - Tank Control Levels for Tanks at New Affected Sources as Required by 40 CFR 63.685(b)(2)

------------------------------------------------------------------------ Maximum HAP vapor Tank design capacity (cubic pressure of off-site Tank control meters) material managed in level tank (kilopascals) ------------------------------------------------------------------------ Design capacity less than 38 m3 Maximum HAP vapor Level 1.

pressure less than 76.6 kPa.

Design capacity equal to or Maximum HAP vapor Level 1.

greater than 38 m3 and less pressure less than than 151 m3. 13.1 kPa.

Maximum HAP vapor Level 2.

pressure equal to or greater than 13.1 kPa.

Design capacity equal to or Maximum HAP vapor Level 1.

greater than 151 m3. pressure less than 0.7 kPa.

Maximum HAP vapor Level 2.

pressure equal to or greater than 0.7 kPa.

------------------------------------------------------------------------