10 CFR 434.504 - Use of the prototype building to determine the energy cost budget.

Code of Federal Regulations - Title 10: Energy

Linked as:

Text


Title 10: Energy

CHAPTER II: DEPARTMENT OF ENERGY

SUBCHAPTER D: ENERGY CONSERVATION

PART 434: ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS

Subpart E: Building Energy Cost Compliance Alternative

434.504 - Use of the prototype building to determine the energy cost budget.

504.1Determine the building type of the Proposed Design using the categories in subsection 503.1. Using the appropriate Prototype Building characteristics from all of the tables contained in Subpart E, the building shall be simulated using the same gross floor area and number of floors for the Prototype Building as in the Proposed Design.

504.2The form, orientation, occupancy and use profiles for the Prototype Building shall be fixed as described in subsection 511. Envelope, lighting, other internal loads and HVAC systems and equipment shall meet the requirements of subsection 301, 401, 402, 403, and 404 and are standardized inputs.