Text
Title 40: Protection of Environment
CHAPTER I: ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)
SUBCHAPTER N: EFFLUENT GUIDELINES AND STANDARDS
PART 430: THE PULP, PAPER, AND PAPERBOARD POINT SOURCE CATEGORY
Subpart I: Secondary Fiber Deink Subcategory
430.96 - Pretreatment standards for existing sources (PSES).(a) Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart that introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for existing sources (PSES) if it uses chlorophenolic-containing biocides. Permittees not using chlorophenolic-containing biocides must certify to the permit-issuing authority that they are not using these biocides. PSES must be attained on or before July 1, 1984:
| Pollutant or pollutant property | PSES | Maximum for any 1 day | Milligrams/liter (mg/l) | Kg/kkg (or pounds per 1,000 lb) of product a |
| Pentachlorophenol | (0.032)(24.4)/y | 0.0033 |
| Trichlorophenol | (0.082)(24.4)/y | 0.0084 |
| y = wastewater discharged in kgal per ton of product. |
| Pollutant or pollutant property | PSES | Maximum for any 1 day | Milligrams/liter (mg/l) | Kg/kkg (or pounds per 1,000 lb) of product a |
| Pentachlorophenol | (0.032)(24.4)/y | 0.0033 |
| Trichlorophenol | (0.010)(24.4)/y | 0.0010 |
| y = wastewater discharged in kgal per ton of product. |