Text
Title 40: Protection of Environment
CHAPTER I: ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)
SUBCHAPTER N: EFFLUENT GUIDELINES AND STANDARDS
PART 430: THE PULP, PAPER, AND PAPERBOARD POINT SOURCE CATEGORY
Subpart B: Bleached Papergrade Kraft and Soda Subcategory
430.25 - New source performance standards (NSPS).
New sources subject to this subpart must achieve the following new source performance standards (NSPS), as applicable.
(a) The following standards apply to each new source that commenced discharge after June 15, 1988 and before June 15, 1998, provided that the new source was constructed to meet these standards:
| Pollutant or pollutant property | Continuous dischargers | Maximum for any 1 day | Average of daily values for 30 consecutive days | Non-continuous dischargers | Annualaverage |
| kg/kkg (or pounds per 1,000 lb) of product | |||
| BOD5 | 10.3 | 5.5 | 2.88 |
| TSS | 18.2 | 9.5 | 5.00 |
| pH | (1) | (1) | (1) |
| Pollutant or pollutant property | Continuous dischargers | Maximum for any 1 day | Average of daily values for 30 consecutive days | Non-continuous dischargers | Annualaverage |
| kg/kkg (or pounds per 1,000 lb) of product | |||
| BOD5 | 8.5 | 4.6 | 2.41 |
| TSS | 14.6 | 7.6 | 4.00 |
| pH | (1) | (1) | (1) |
| Pollutant or pollutant property | Continuous dischargers | Maximum for any 1 day | Average of daily values for 30 consecutive days | Non-continuous dischargers | Annualaverage |
| kg/kkg (or pounds per 1,000 lb) of product | |||
| BOD5 | 5.7 | 3.1 | 1.62 |
| TSS | 9.1 | 4.8 | 2.53 |
| pH | (1) | (1) | (1) |
(b) Except as provided in paragraph (c) of this section?
(1) The following standards apply with respect to each new source fiber line that does not use an exclusively TCF bleaching process, as disclosed by the discharger in its NPDES permit application under 40 CFR 122.21(g)(3) and certified under 40 CFR 122.22, and that commences discharge after June 15, 1998:
| Pollutant or pollutant property | NSPS | Maximum for any 1 day | Monthlyaverage |
| TCDD | <ML a | (b) |
| TCDF | 31.9 c | (b) |
| Chloroform | 6.92 d | 4.14 d |
| Trichlorosyringol | <ML a | (b) |
| 3,4,5-trichlorocatechol | <ML a | (b) |
| 3,4,6-trichlorocatechol | <ML a | (b) |
| 3,4,5-trichloroguaiacol | <ML a | (b) |
| 3,4,6-trichloroguaiacol | <ML a | (b) |
| 4,5,6-trichloroguaiacol | <ML a | (b) |
| 2,4,5-trichlorophenol | <ML a | (b) |
| 2,4,6-trichlorophenol | <ML a | (b) |
| Tetrachlorocatechol | <ML a | (b) |
| Tetrachloroguaiacol | <ML a | (b) |
| 2,3,4,6-tetrachlorophenol | <ML a | (b) |
| Pentachlorophenol | <ML a | (b) |
| Continuous dischargers | Maximum for any 1 day (kg/kkg) | Monthly average (kg/kkg) | Non-continuous dischargers | Annual average (kg/kkg) |
| AOX | 0.476 | 0.272 | 0.208 |
| BOD5 | 4.52 | 2.41 | 1.73 |
| TSS | 8.47 | 3.86 | 2.72 |
| pH | (1) | (1) | (1) |
| COD | (e) | (e) | (e) |
(2) The following standards apply with respect to each new source fiber line that uses exclusively TCF bleaching processes, as disclosed by the discharger in its NPDES permit application under 40 CFR 122.21(g)(3) and certified under 40 CFR 122.22, and that commences discharge after June 15, 1998:
| Pollutant or pollutant property | NSPS (TCF) | Continuous dischargers | Maximum for any 1 day | Monthlyaverage | Non-continuousdischargers | Maximum for any 1 day | Annualaverage |
| AOX | <ML a | (b) | <ML a | (b) |
| BOD5 | 4.52 d | 2.41 | N/A | 1.73 |
| TSS | 8.47 d | 3.86 | N/A | 2.72 |
| pH | (1) | (1) | (1) | (1) |
| COD | (c) | (c) | (c) | (c) |
(c) With respect to each new source fiber line that is enrolled in the Voluntary Advanced Technology Incentives Program, dischargers subject to this section must achieve:
(1) The standards specified in paragraph (b)(1) of this section (except for AOX) or paragraph (b)(2) of this section, as applicable; and
(2) Standards for filtrates, flow, and AOX:
| Tier | Filtrate recycling | Total pulping area condensate, evaporator condensate, and bleach plant wastewater flow (annual average) | AOX (kg/kkg) | Non-TCF a | Maximum for any 1 day | Annual average | TCF | Maximum for any 1 day | Annual average |
| Tier II | (b) | 10 cubic meters/kkg | 0.23 | 0.10 | <ML c | (d) |
| Tier III | (b) | 5 cubic meters/kkg | 0.11 | 0.05 | <ML c | (d) |
(d) These additional standards apply to all new sources, regardless of when they commenced discharge, in accordance with the previous subcategorization scheme unless the discharger certifies to the permitting authority that it is not using these compounds as biocides. Also, for non-continuous dischargers, concentration limitations (mg/l) shall apply. Concentration limitations will only apply to non-continuous dischargers:
| Pollutant or pollutant property | Maximum for any 1 day | kg/kkg (or pounds per 1,000 lb) of product | Milligrams/liter |
| Pentachlorophenol | 0.0019 | (0.013)(36.6)/y |
| Trichlorophenol | 0.012 | (0.077)(36.6)/y |
| y = wastewater discharged in kgal per ton of product. |
| Pollutant or pollutant property | Maximum for any 1 day | kg/kkg (or pounds per 1,000 lb) of product | Milligrams/liter |
| Pentachlorophenol | 0.0016 | (0.012)(31.7)/y |
| Trichlorophenol | 0.010 | (0.076)(31.7)/y |
| y = wastewater discharged in kgal per ton of product. |
| Pollutant or pollutant property | Maximum for any 1 day | kg/kkg (or pounds per 1,000 lb) of product | Milligrams/liter |
| Pentachlorophenol | 0.0014 | (0.014)(25.1)/y |
| Trichlorophenol | 0.0088 | (0.084)(25.1)/y |
| y = wastewater discharged in kgal per ton of product. |
(e) Pursuant to 40 CFR 122.44(i) and 122.45(h), a discharger must demonstrate compliance with the limitations in paragraph (b)(1) or (c)(1) of this section, as applicable, by monitoring for all pollutants (except for AOX, COD, BOD5, TSS, and pH) at the point where the wastewater containing those pollutants leaves the bleach plant. The permitting authority may impose effluent limitations and/or monitoring requirements on internal wastestreams for any other pollutants covered in this section as appropriate under 40 CFR 122.44(i) and 122.45(h). In addition, a discharger subject to a limitation on total pulping area condensate, evaporator condensate, and bleach plant wastewater flow under paragraph (c)(2) of this section must demonstrate compliance with that limitation by establishing and maintaining flow measurement equipment monitoring these flows at the point or points where they leave the pulping area, evaporator area, and the bleach plant.
[63 FR 18635, Apr. 15, 1998; 63 FR 42239, Aug. 7, 1998]
Sponsored links
This document cites
- Code of Federal Regulations - Title 40: Protection of Environment - 40 CFR 122.44 - Establishing limitations, standards, and other permit conditions (applicable to State NPDES programs, see § 123.25).
- Code of Federal Regulations - Title 40: Protection of Environment - 40 CFR 122.21 - Application for a permit (applicable to State programs, see § 123.25).
- Code of Federal Regulations - Title 40: Protection of Environment - 40 CFR 122.22 - Signatories to permit applications and reports (applicable to State programs, see § 123.25).
See other documents that cite the same legislation