TITLE 16 - COMMERCIAL PRACTICES

CHAPTER I - FEDERAL TRADE COMMISSION

SUBCHAPTER C - REGULATIONS UNDER SPECIFIC ACTS OF CONGRESS

PART 305 - RULE CONCERNING DISCLOSURES REGARDING ENERGY CONSUMPTION AND WATER USE OF CERTAIN HOME APPLIANCES AND OTHER PRODUCTS REQUIRED UNDER THE ENERGY POLICY AND CONSERVATION ACT (''APPLIANCE LABELING RULE'')

Appendix I to Part 305 - Heating Performance and Cost for Central Air Conditioners

1. Range Information ------------------------------------------------------------------------ Range of HSPF's Manufacturer's rated heating capacity (Btu's/ ------------------------- hr.) Low High ------------------------------------------------------------------------ Single Package Units Heat Pumps (Heating Function): All capacities. 7.00 8.20 Split System Units Heat Pumps (Heating Function): All capacities. 7.10 10.55 ------------------------------------------------------------------------ The HSPF shall be the Region IV value based on the appropriate average design heat loss from the table below.

2. Yearly Heating Cost Information: For each model, display a regional annual operating cost, based on 9.06 per kilowatt hour, rounded to the nearest $10, calculated according to 10 CFR 430.22(m)(3)(ii) for each region. The heat loss of home values given in the chart below are to be considered standardized design heating requirements in the calculation of annual operating cost in accordance with 10 CFR 430.22(m)(3)(ii).

---------------------------------------------------------------------------------------------------------------- Average design heat Capacity Region loss (in Heat loss of home values used on 1000's the grid (in 1000's Btu's/hr.) Btu's/hr.) ---------------------------------------------------------------------------------------------------------------- Up to 9,000............................................ 1 10 5, 10 2 5, 10, 15 3 5, 10, 15 4 10, 15, 20 5 10, 15, 20 6 5, 10, 15 9,100 to 15,000........................................ 1 20 5, 10, 15 2 5, 10, 15, 20 3 10, 15, 20, 25 4 10, 15, 20, 25, 30 5 10, 15, 20, 25, 30 6 5, 10, 15, 20 15,100 to 21,000....................................... 1 25 10, 15, 20 2 10, 15, 20, 25 3 15, 20, 25, 30 4 15, 20, 25, 30, 35, 40 5 15, 20, 25, 30, 35, 40 6 10, 15, 20, 25, 30, 35 21,100 to 27,000....................................... 1 30 10, 15, 20, 25 2 15, 20, 25, 30 3 15, 20, 25, 30, 35, 40 4 20, 25, 30, 35, 40, 50 5 20, 25, 30, 35, 40, 50, 60 6 10, 15, 20, 25, 30, 35 21,100 to 27,000....................................... 1 30 10, 15, 20, 25 2 15, 20, 25, 30 3 15, 20, 25, 30, 35, 40 4 20, 25, 30, 35, 40, 50 5 20, 25, 30, 35, 40, 50, 60 6 15, 20, 25, 30, 35, 40 27,100 to 33,000....................................... 1 35 15, 20, 25, 30 2 20, 25, 30, 35, 40 3 20, 25, 30, 35, 40, 50 4 25, 30, 35, 40, 50, 60 5 25, 30, 35, 40, 50, 60, 70, 80 6 20, 25, 30, 35, 40, 50, 60 33,200 to 39,000....................................... 1 50 15, 20, 25, 30, 35 2 25, 30, 35, 40, 50 3 30, 35, 40, 50, 60 4 35, 40, 50, 60, 70, 80, 90 5 35, 40, 50, 60, 70, 80, 90 6 25, 30, 35, 40, 50 39,500 to 45,000....................................... 1 60 20, 25, 30, 35, 40 2 25, 30, 35, 40, 50, 60 3 30, 35, 40, 50, 60 4 40, 50, 60, 70, 80, 90, 100 5 40, 50, 60, 70, 80, 90, 100, 110 6 25, 30, 35, 40, 50, 60, 70, 80 45,500 to 51,000....................................... 1 70 20, 25, 30, 35, 40 2 30, 35, 40, 50, 60 3 35, 40, 50, 60, 70, 80 4 50, 60, 70, 80, 90, 100, 110 5 50, 60, 70, 80, 90, 100, 110, 130 6 30, 35, 40, 50, 60, 70, 80, 90, 100, 110, 130 51,500 to 57,000....................................... 1 70 25, 30, 35, 40, 50 2 35, 40, 50, 60, 70 3 40, 50, 60, 70, 80, 90 4 50, 60, 70, 80, 90, 100, 110 5 50, 60, 70, 80, 90, 100 ,110, 130 6 35, 40, 50, 60, 70, 80, 90, 100 57,500 to 63,000....................................... 1 80 25, 30, 35, 40, 50 2 35, 40, 50, 60, 70 3 50, 60, 70, 80, 90 4 60, 70, 80, 90, 100, 110 5 60, 70, 80, 90, 100, 110, 130 6 35, 40, 50, 60, 70, 80, 90, 100 63,500 and over........................................ 1 90 30, 35, 40, 50, 60 2 40, 50, 60, 70, 80 3 50, 60, 70, 80, 90, 100 4 70, 80, 90, 100, 110, 130 5 70, 80, 90, 100, 110, 130 6 40, 50, 60, 70, 80 ---------------------------------------------------------------------------------------------------------------- Include the following note on every fact sheet page that lists annual operating costs.

Note: These annual heating costs are based on U.S. Government standard tests and on a national average cost of electricity of 9.06/KWH. Your cost will vary depending on your local energy rate and how you use the product. A method for estimating your cost of operation is given [direct user to location].

The methodology referred to in the note is provided below. This information shall be included at least once in all compendiums of fact sheets. If separate fact sheets are prepared for individual distribution to consumers, this methodology must be provided on or with the unbound fact sheets.

How To Estimate Your Heating Costs To estimate your heating cost, determine your cost of electricity in cents per kilowatt hour (KWH) from your electric bill, your listed average annual heating cost from the National Average Annual Heating Cost Table, and use that number in the following equation: (image) Example: If your electric rate is 12.62/KWH and the annual heating cost listed in the chart is $200: Your estimated cost = $200 13.6/9.06 Your estimated cost = $200 1.5 = $300 Your estimated cost = $300 (image) View or download PDF (image) View or download PDF Note: These annual heating costs are based on U.S. Government standard tests and on a national average cost of electricity of 9.06/KWH. Your cost will vary depending on your local energy rate and how you use the product. A method for estimating your cost of operation is given below.

How To Estimate Your Heating Cost To estimate your heating cost, determine your cost of electricity in cents per kilowatt hour (KWH) from your electric bill, your listed average annual heating cost from the National Average Annual Heating Cost Table, and substitute that number in the following equation: (image) Example: If your electric cost is 13.6/KWH and the annual heating cost listed in the table is $200: Your estimated cost = $200 13.6/9.06 Your estimated cost = $200 1.5 = $300 Your estimated cost = $300 (This is page 2 of sample fact sheet) [53 FR 19729, May 27, 1988, as amended at 54 FR 53318, Dec. 28, 1989; 55 FR 43093, Oct. 26, 1990; 56 FR 46728, Sept. 16, 1991; 57 FR 44332, Sept.

25, 1992; 59 FR 34051, July 1, 1994; 59 FR 39952, Aug. 5, 1994; 60 FR 56949, Nov. 13, 1995; 61 FR 48623, Sept. 16, 1996; 62 FR 44891, Aug. 25, 1997; 64 FR 926, Jan. 6, 1999; 64 FR 71021, Dec. 20, 1999; 65 FR 53166, Sept. 1, 2000; 66 FR 49531, Sept. 28, 2001; 66 FR 57872, Nov. 19, 2001; 67 FR 58328, Sept. 16, 2002; 68 FR 47451, Aug. 11, 2003; 69 FR 54560, Sept. 9, 2004; 70 FR 32487, June 3, 2005; 70 FR 60718, Oct. 19, 2005]

Sponsored Ads:




Activate your free trial now

Make your order

Need help? Contact us

Try vLex for FREE for 3 days

Access legal information from United States including:

  • Constitutions
  • Forms and Contracts
  • Legal Books and Journals
  • Case Law
  • News and Business
  • Regulations
  • U.S. Code

Try vLex without any commitment for 3 days and see why you need it.

3

days of Free Access