183.425 - Conductors: General.

(a) Each conductor must be insulated, stranded copper.

(b) Except for intermittent surges each conductor must not carry a current greater than that specified in Table 5 for the conductor's gauge and temperature rating.

(c) For conductors in engine spaces, amperages must be corrected by the appropriate correction factor in note 1 of Table 5.

(d) Each conductor in a multiconductor sheath must be at least a No. 18 AWG conductor.

(e) Each conductor installed separately must be at least a No. 16 AWG conductor.

(f) Each No. 18 AWG conductor in a multiconductor sheath may not extend out of the sheath more than 30 inches.

(g) This section does not apply to communications systems; electronic navigation equipment; electronic circuits having a current flow of less than one ampere; conductors which are totally inside an equipment housing; resistance conductors that control circuit amperage; high voltage secondary conductors and terminations that are in ignition systems; pigtails of less than seven inches of exposed length and cranking motor conductors.

Table 5?Allowable Amperage of Conductors
Conductor size (AWG)Temperature rating of conductor insulation60 ?C (140 ?F)75 ?C (167 ?F)80 ?C (176 ?F)90 ?C (194 ?F)105 ?C (221 ?F)125 ?C (257 ?F)200 ?C (392 ?F)
1810101520202525
1615152025253035
1420202530354045
1225253540455055
1040405055607070
8556570708090100
68095100100120125135
4105125130135160170180
3120145150155180195210
2140170175180210225240
1165195210210245265280
0195230245245285305325
00225265285285330355370
000260310330330385410430
0000300360385385445475510


NOTES

1. See the following table:60 ?C75 ?C80 ?C90 ?C105 ?C125 ?C200 ?C


(140 ?F)(167 ?F)(176 ?F)(194 ?F)(221 ?F)(257 ?F)(392 ?F)
Temperature rating of conductor0.580.750.780.820.850.891.00

2. See the following table:

Correction





factor

Number of current carrying conductors:
30.70
4 to 6.60
7 to 24.50
25 and above.40