46 CFR 171.073 - Treatment of stepped and recessed bulkheads in Type II subdivision.

Code of Federal Regulations - Title 46: Shipping

Linked as:

Text


Title 46: Shipping

CHAPTER I: COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED)

SUBCHAPTER S: SUBDIVISION AND STABILITY

PART 171: SPECIAL RULES PERTAINING TO VESSELS CARRYING PASSENGERS

Subpart C: Large Vessels

171.073 - Treatment of stepped and recessed bulkheads in Type II subdivision.

(a) A main transverse watertight bulkhead may not be stepped unless additional watertight bulkheads are located as shown in Figure 171.067(a) so that the distances A, B, C, and D illustrated in Figure 171.067(a) comply with the following:

(1) A and B must not exceed the maximum bulkhead spacing that permits compliance with ? 171.070; and

(2) C and D must not be less than the minimum spacing specified in ? 171.070(e).

(b) A main transverse watertight bulkhead may not be recessed unless all parts of the recess are inboard from the shell of the vessel as illustrated in Figure 171.067(c).

(c) If a main transverse watertight bulkhead is recessed or stepped, an equivalent plane bulkhead must be used in the calculations required by ? 171.070.

Sponsored links