33 CFR 159.121 - Sewage processing test.
Code of Federal Regulations - Title 33: Navigation and Navigable Waters (2010)
Linked as:Code of Federal Regulations - Title 33: Navigation and Navigable Waters (2010)
Linked as:
Text
Title 33: Navigation and Navigable Waters
CHAPTER I: COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED)
SUBCHAPTER O: POLLUTION
PART 159: MARINE SANITATION DEVICES
Subpart C: Design, Construction, and Testing
159.121 - Sewage processing test.
(a) The device must process human sewage in the manner for which it is designed when tested in accordance with this section. There must be no sewage or sewage-treating chemicals remaining on surfaces or in crevices that could come in contact with a person using the device or servicing the device in accordance with the instructions supplied under ? 159.57(b)(7).
(b) During the test the device must be operated and maintained in accordance with the manufacturer's instructions. Any initial start-up time specified by the manufacturer must be allowed before test periods begin. For 1 hour of each 8-hour test period, the device must be tilted to the maximum angles specified by the manufacturer under ?? 159.55 and 159.57.
(c) Except for devices described in paragraph (d) of this section, the devices must process and discharge or store human sewage over at least an 8-consecutive hour period on at least 10 days within a 20-day period. The device must receive human sewage consisting of fecal matter, urine, and toilet paper in a ratio of four urinations to one defecation with at least one defecation per person per day. Devices must be tested at their average rate of capacity as specified in ? 159.57. In addition, during three periods of each day the system must process sewage at the peak capacity for the period of time it is rated at peak capacity.
(d) A device that processes and discharges continuously between individual use periods or a large device, as determined by the Coast Guard, must process and discharge sewage over at least 10-consecutive days at the average daily capacity specified by the manufacturer. During three periods of each day the system must process sewage at the peak capacity for the period of time it is rated at peak capacity. The sewage for this test must be fresh, domestic sewage to which primary sludge has been added, as necessary, to create a test sewage with a minimum of 500 milligrams of suspended solids per liter.
[CGD 73-83, 40 FR 4624, Jan. 30, 1975, as amended by USCG-2002-12471, 67 FR 41333, June 18, 2002]
ver las páginas en versión mobile | web
ver las páginas en versión mobile | web
© Copyright 2013, vLex. All Rights Reserved.
Contents in vLex United States
Explore vLex
For Professionals
For Partners
Company
Other documents:
hitting home. | more employers providing domestic partner benefits. | indymac lowers outlook for third quarter gaaps eps. | lglr offers intense course in all things little rock: class members learn leadership skills, different aspects of city. | Decisión de Tribunal Tercero de Primera Instancia en Funciones de Control de Sucre (Extensión Carupano)... | Decisión nº WP01-P-2004-400 de Juzgado Cuarto de Juicio de Vargas, de August 06, 2004 | decisión de juzgado segundo de primera instancia en lo civil, mercantil y transito los teques de miranda, de march 08, 2004 | Decisión de Juzgado Superior en lo Civil, Mercantil, Transito y de Menores de Miranda, de February 05, 2004